Model |
DOS-72F
|
DOS-102F
|
DOS-152F
|
DOS-202F
|
Acquisition |
Sample Modes |
Real-Time Sample
|
Acquisition Modes |
|
Normal |
Normal data only
|
Peak Detect |
High-frequency and randon glith capture
|
Average |
Wavefom Average, selectable 4,8,16,32,64,128
|
Inputs |
Inputs Coupling |
AC, DC, GND
|
Inputs Impendance |
1MΩ±2% ‖20pF±3pF
|
Probe Attenuation |
1X, 10X
|
Supported Probe Attenuation Factor |
1X, 10X, 100X, 1000X
|
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×)
|
Horizontal System |
Sample Rate Range |
1GS/s
|
Waveform Interpolation |
(sin x)/x
|
Record Length |
2M
|
SEC/DIV Range |
4ns/div~2000s/div, in a 2, 4, 8 sequence
|
2ns/div~2000s/div, in a 2, 4, 8 sequence
|
Sample Rate and
Delay Time Accuracy |
±50ppm over any ≥1ms time interval
|
Scanning Speed Range |
4ns/div to 8ns/div; (-8div x s/div) to 40ms;
20ns/div to 80μs/div;(-8div×s/div) to 40ms
200μs/div to 40s/div; (-8div×s/div) to 400s
|
2ns/div to10ns/div;
(-4div×s/div) to 20ms;
|
Delta Time Measurement Accuracy
(Full Bandwidth) |
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
|
Vertical System |
Vertical Resolution |
8-bit resolution, all channel sampled simultaneously
|
Volts Range |
2mV/div to 100V/div at input BNC
|
Bandwidth |
70MHz
|
100MHz
|
150MHz
|
200MHz
|
Rise Time at BNC( typical) |
5ns
|
3.5ns
|
2.3ns
|
1.8ns
|
Analog Bandwidth in
Normal and Average
modes at BNC or with probe,
DC Coupled |
±400V(100V/div-20V/div);
±50V(10V/div-5V/div)
±40V(2V/div-500mV/div);
±2V(200mV/div-50mV/div)
±400mV(20mV/div-2mV/div)
|
Math |
+, -, *, /, FFT
|
FFT |
Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
|
Bandwidth Limit |
20MHz
|
Low Frequency Response (-3db) |
≤10Hz at BNC
|
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
|
DC Measurement Accuracy,
Average Acquisition Mode |
Measurement Type: Average of ≥16 waveforms with vertical position at zero
Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.
Measurement Type: Average of ≥16 waveforms with vertical position not at zero
Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].
|
Volts Measurement Repeatability,
Average Acquisition Mode |
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
|
Trigger System |
Trigger Types |
Edge, Video, Pulse, Slope, Over time, Alternative
|
Trigger Source |
CH1, CH2, AC Line
|
Trigger Modes |
Auto, Normal, Single
|
Coupling Type |
DC, AC, HF Reject, LF Reject, Noise Reject
|
Trigger Sensitivity
(Edge Trigger Type) |
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
AC: Attenuates signals below 10Hz ;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.
|
Trigger Level Range |
CH1/CH2: ±8 divisions from center of screen;
|
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns |
CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
|
Set Level to 50%(typical) |
Operates with input signals ≥50Hz
|
Video Trigger |
|
Video Trigger Type |
CH1, CH2: Peak-to-peak amplitude of 2 divisions;
|
Signal Formats and Field Rates |
Supports NTSC, PAL and SECAM broadcast systems for any field or any line
|
Holdoff Range |
100ns ~ 10s
|
Pulse Width Trigger |
|
Pulse Width Trigger Mode |
Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
|
Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
|
Pulse Width Range |
20ns ~ 10s
|
Slope Trigger |
|
Slope Trigger Mode |
Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
|
Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
|
Time Range |
20ns ~ 10s
|
Overtime Trigger |
|
Over Time Modee |
Rising edge or Falling edge
|
Time Range |
20ns ~ 10s
|
Alternative Trigger |
|
Trigger on CH1 |
Internal Trigger: Edge, Pulse Width, Video, Slope
|
Trigger on CH2 |
Internal Trigger: Edge, Pulse Width, Video, Slope
|
Trigger Frequency Counter |
|
Readout Resolution |
6 digits
|
Accuracy (typical) |
±30ppm (including all frequency reference errors and ±1 count errors)
|
Frequency Range |
AC coupled, from 4Hz minimum to rated bandwidth
|
Signal Source |
Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
|
Measure |
Cursor Measurement |
Manual: Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT);
Tracing: The valtage and time at a waveform point;
|
Auto Measuerment |
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
|
Scope Trendplot |
1.2M Point
|
General Specifications |
Display Resolution |
640 horizontal by 480 vertical pixels
|
Display Contrast |
Adjustable (16 gears) with the progress bar
|
Probe Compensator Output |
|
Output Voltage( typical) |
About 2Vpp into ≥1MΩ load
|
Frequency(typical) |
1kHz
|
Power Supply |
|
Supply Voltage |
AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A
|
Power Consumption |
<30W
|
Environmental |
|
Temperature |
Operating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
|
Cooling Method |
Convection
|
Humidity |
+104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
|
Altitude |
Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
|
Mechanical |
|
Size |
260mmmm; 220mm; 75mm
|
Weight |
2.5KG(without Packing)
|