GC-500 -Series

QUICK OVERVIEW

Product Code: 12369
Brand: Gas chromatography

GC-500 Series 


Share this product on social networks

Standard PC-side anti-control software, built-in color spectrum workstation, to achieve PC-side anti-control and host touch screen synchronous two-way control. (GC112N only)

The host uses a 7-inch color touch screen that electronically displays the flow value and pressure value of the air path.

Lack of gas alarm: the user uses the middle shift column, open the door, the motor and heating all stop, improve safety and security.

According to user requirements, the work diversion ratio is large, the non-working shunt ratio is small, saving gas.

The automatic sample entry has a positioning function, and the sample is more efficient and accurate.

Multi-core, 32-bit embedded hardware system, to ensure the reliable operation of the instrument.

One-click start function, with 20 sets of sample test way memory function.

Using logaripart amplification board, the extensible synchronous external trigger function can be activated by the external signal (autosampler, thermal parser, etc.) at the same time the host and workstation.

It has a perfect system self-test function and automatic fault identification function.

With 8 external events of the extended function interface, can select a variety of function control valves, and according to their own set timing work.

RS232 communication port and LAM net port, and configuration data acquisition card.

Column temperature box:

Content product: 22L

Temperature control range: 5c – 400C at room temperature

Temperature-controlled accuracy: .1 oC

Heating rate: 0.1 – 60C / min

The stage of program heating: 9

The repetitiveness of the program heating: 2%

Cooling mode: Open the door after

Cooling speed: 10 mins (250 degrees C-50 degrees C)

Sampler:

Temperature control range: 7c – 420C at room temperature

Temperature control: independent temperature control

Air-carrying flow control: constant pressure

Number of simultaneous installations: up to 3

Type of sample unit: fill column, shunt

Shunt ratio: shunt ratio display

Column pressure range: 0 – 400kpa

Column pressure control accuracy: 0.1kpa

Flow setting range:H20-200ml / min N20-150ml / min

Detector:

FID, TCD, any choice

Temperature control range: 7c – 420C at room temperature

Number of simultaneous installations: up to 2

Ignition function: Automatic

Hydrogen flame ionization detector (FID):

Detection limit: s 3 x10-12 g / s (positive xane)

Baseline noise: s 5 x10-14 A

Baseline Drift: s 6 x10-13A

Dynamic range:107

RSD: s 3%

Thermal Guide Detector (TCD):

Sensitivity: 5000mV.ml / mg (positive xane)

Baseline noise: . . . . . . . . . . . . . .

Baseline Drift: . . . . . . . . . . . . . . . . . . . .

Dynamic range:105

Supply voltage: 220V to 22V, 50Hz to 0.5Hz

Power: 3000W

TECHNICAL SPECIFICATION

GC-500FSingle FID, LCD display, 7-400℃, RS232
GC-500TSingle TCD, LCD display, 7-400℃, RS232
GC-500FTFID & TCD, LCD display, 7-400℃, RS232