UPS-L Series

Product Code: 99967
Brand:On Line UPS

UPS-L Series

Description

 

  • Really achieve online double conversion
  • The microprocessor control technoloensuresthehighperformanc e
    Input power factor correction
  • Output power factor of 0.8
  • Wide input voltage (110 V to 300 V)
  • Efficient variable frequency conversion mode
  • ECO mode (1-3 K only)
  • Compatible with the generator input
  • The optional exquisite SNMP card can perfectly monitor and
  • control through the display alone or together with USB and RS232,
    and comprehensively display and monitor the UPS status

TECHNICAL SPECIFICATION

MODEL UPS1000L UPS2000L UPS3000L UPS6000L UPS 10000L
PHASE Single hand to hand
CAPACITY 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000VA/4800W 10000VA/800W
INPUT
Nominal Voltage 200/208/220/230/240VA 208/220/230/240VAC
Input Voltage Range 110 -300VAC or 50% load ; 160 -280 VAC or 100% load 110 -300VAC or 50% load ; 176-300 VAC or 100% load
Frequency Range 40Hz ~70Hz 46~54Hz or 56~64Hz
Power Factor

 (100% load) ≧0.99

OUTPUT
Output Voltage 200/208/220/230/240VAC 208/220/230/240VAC
Voltage Regulation

± 1%

Frequency Range (Synchronized Range) 47-53Hz or 57-63Hz 46-54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50Hz±0.25Hz or 60Hz±0.3Hz 50 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio

3:1

Harmonic Distortion ≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
≦ 3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Transfer Time AC to DC

Zero

Inverter to Bypass 4 ms (Typical) Zero
Wave Form (Batt. Mode)

Pure Sine wave

EFFICIENCY
To AC Mode 88% 89% 90% 92% 93%
To Battery Mode 83% 87% 88% 90% 91%
BATTERY
Standard Model Battery Type

12V/9AH/7AH

Numbers 2 4 6 16 16
Charging Current (max.) 1 A 1A/2A
Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1%
Long-run Model* Battery Type

Depending on the capacity of external batteries

Numbers 3 6 8 16 ~ 20 ( A d j u s t a b l e )
Charging Current (max.) 1A/2A/4A/6A (Adjustable) 1A/2A/4A/6A ( A d j u s t a b l e , 6A i s only available for16pcs batteries
Charging Voltage 41.0VDC ± 1% 82.1 VDC ±1% 109.4VDC ±1% 218.4 VDC ±1% 273VDC ± 1% 218.4VDC ± 1% 273VDC ± 1%
INDICATORS
LCD

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

ALARM
Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continously sounding

PHYSICAL
Standard Model Dimension, D x W x H (mm) 282*145*220 397*145*220 369*190*318 442*190*688
Net Weight (kgs) 8.7 15.7 24.6 61 66
Long-run Model* Dimension, D x W x H (mm) 282*145*220 397*145*240 369*190*318 442*190*318
Net Weight (kgs) 4.1 6.8 7.4 12 16
ENVIRONMENT
Humidity 20-90 % RH @ 0- 40°C (non-condensing) 0-95% RH@0-40°C (non-condensing)
Noise Level Less than 50 DB@ 1 m Less than 55 DB @ 1 m

Less than 58 dBA @ 1 m

MANAGEMENT
Smart RS-232/USB

Windows ® 2000/2003/XP/Vista/2008,Windows® 7/8, Unix and MAC

Optional SNMP

Power management from SNMP manager and web browser

 

When 1-3L UPS is set to constant voltage and constant frequency mode, the output power will drop by 20%, and when the output voltage of the UPS is set to 208VAC, the output

power will drop by 20%.

When 6 / 10L UPS is set to constant voltage and constant frequency mode, the output power drops by 40%, and when the output voltage of the UPS is set to 208VAC, the output

power amount drops by 10%.* * When the number of internal batteries e machine will derate the output according to the following formula: P=Prating X (N / 20 x 100%).

If the machine is installed above 1000 meters, every 100M increases.

Changes in the current product specifications will not be notified separately