TECHNICAL SPECIFICATION

MODELUPS1000LUPS2000LUPS3000LUPS6000LUPS 10000L
PHASESingle hand to hand
CAPACITY1000 VA / 800 W2000 VA / 1600 W3000 VA / 2400 W6000VA/4800W10000VA/800W
INPUT
Nominal Voltage200/208/220/230/240VA208/220/230/240VAC
Input Voltage Range110 -300VAC or 50% load ; 160 -280 VAC or 100% load110 -300VAC or 50% load ; 176-300 VAC or 100% load
Frequency Range40Hz ~70Hz46~54Hz or 56~64Hz
Power Factor

 (100% load) ≧0.99

OUTPUT
Output Voltage200/208/220/230/240VAC208/220/230/240VAC
Voltage Regulation

± 1%

Frequency Range (Synchronized Range)47-53Hz or 57-63Hz46-54Hz or 56-64Hz
Frequency Range (Batt. Mode)50Hz±0.25Hz or 60Hz±0.3Hz50 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio

3:1

Harmonic Distortion≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
≦ 3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Transfer TimeAC to DC

Zero

Inverter to Bypass4 ms (Typical)Zero
Wave Form (Batt. Mode)

Pure Sine wave

EFFICIENCY
To AC Mode88%89%90%92%93%
To Battery Mode83%87%88%90%91%
BATTERY
Standard ModelBattery Type

12V/9AH/7AH

Numbers2461616
Charging Current (max.)1 A1A/2A
Charging Voltage27.4VDC ± 1%54.7 VDC ±1%82.1 VDC ±1%218.4 VDC ±1%
Long-run Model*Battery Type

Depending on the capacity of external batteries

Numbers36816 ~ 20 ( A d j u s t a b l e )
Charging Current (max.)1A/2A/4A/6A (Adjustable)1A/2A/4A/6A ( A d j u s t a b l e , 6A i s only available for16pcs batteries
Charging Voltage41.0VDC ± 1%82.1 VDC ±1%109.4VDC ±1%218.4 VDC ±1%273VDC ± 1%218.4VDC ± 1%273VDC ± 1%
INDICATORS
LCD

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

ALARM
Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continously sounding

PHYSICAL
Standard ModelDimension, D x W x H (mm)282*145*220397*145*220369*190*318442*190*688
Net Weight (kgs)8.715.724.66166
Long-run Model*Dimension, D x W x H (mm)282*145*220397*145*240369*190*318442*190*318
Net Weight (kgs)4.16.87.41216
ENVIRONMENT
Humidity20-90 % RH @ 0- 40°C (non-condensing)0-95% RH@0-40°C (non-condensing)
Noise LevelLess than 50 DB@ 1 mLess than 55 DB @ 1 m

Less than 58 dBA @ 1 m

MANAGEMENT
Smart RS-232/USB

Windows ® 2000/2003/XP/Vista/2008,Windows® 7/8, Unix and MAC

Optional SNMP

Power management from SNMP manager and web browser

 

When 1-3L UPS is set to constant voltage and constant frequency mode, the output power will drop by 20%, and when the output voltage of the UPS is set to 208VAC, the output

power will drop by 20%.

When 6 / 10L UPS is set to constant voltage and constant frequency mode, the output power drops by 40%, and when the output voltage of the UPS is set to 208VAC, the output

power amount drops by 10%.* * When the number of internal batteries e machine will derate the output according to the following formula: P=Prating X (N / 20 x 100%).

If the machine is installed above 1000 meters, every 100M increases.

Changes in the current product specifications will not be notified separately