Porduct introduction :
PPM-1 Plant photosynthetic meter can test CO2,air temperature,humidity,plant leaftemeprature,illumination,air flow etc parameters,
and then calculate plant photosyntheticratio,leaf evaporation,Stomata Conductance or CO2 sub stomata etc.
It widely used infields of Biology,Agriculture,Gardening,Forestry,Inset,Microorganism,Animal etc.
Measuring parameters :
- The dispersive infrared CO2 analysis
- Leaf temperature
- PAR
- Leaf chamber temperature
- Leaf chamber moisture
Calculation :
- Leaf photosynthetic rate(breathing)
- Leaf evaporation rate
- CO2 sub stomata
- Stomata conductance
- Efficiency of water application
Technical parameter :
CO2 analysis:
The dispersive infrared CO2 analysis,measuring range:0-2000ppm,Resolution:0.1ppm;
Accuracy < 0.5ppm when 300ppm , Accuracy 1ppm when 300-800ppm;Accuracy 3ppm when 800-2000ppm
Leaf chamber temperature:
Germany Heraeus high accuracy digital temperature sensor,measuring range:0-60℃,Resolution:0.1℃,Error : ±0.2℃
Leaf temperature:
Platinum resistor,measuring range:0-60℃,Resolution:0.1℃,Error ±0.2℃
Leaf Moisture:
Switzerland high accuracy digital moisture sensor : Measuring range :0-100%,Resolution :0.1%,Error ≤ 1%
PAR:
Photocell with a fixed filter,