MPM-50B

QUICK OVERVIEW

Product Code: 1163
Brand: Multi Parameter

MPM-50B


Share this product on social networks

Benchtop Multiparameter Water Quality Meter

High accuracy multiparameter water quality meter includes 15 optional parameters, the meter is suitable for measuring the pH, ORP, Ion concentration, Conductivity, TDS, Salinity, Resistivity and Dissolved Oxygen of the liquids.

pH Mode:
• High accuracy benchtop multiparameter water quality meter is equipped with a large backlitLCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
• 
Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.

Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units including the ppm, mg/L and mol/L.

Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion factors, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.

Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 15 parameters, including the calibration points, resolutions, stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.

Technical Specification

   Model

MPM-50B

pH

   Range

-2.000~20.000pH

   Accuracy

±0.002pH

   Resolution

0.1, 0.01, 0.001pH

   Calibration Points

1 to 5 points, USA, NIST, DIN Standards

   Temperature Compensation

0~100°C, 32~212°F, Manual or Automatic

mV

   Range

-1999.9~1999.9mV

   Accuracy

±0.2mV

   Resolution

0.1, 1mV

   Calibration Points

1 point (Only for Relative mV mode)

   Calibration Range

±200mV

Ion

   Range

0.001~19999ppm, mg/L, mol/L

(Depending on range of ISE)

   Accuracy

±0.5% F.S (Monovalent), ±1% F.S (Divalent)

   Resolution

0.001, 0.01, 0.1, 1

   Calibration Points

2 to 5 points

   Calibration Solutions

0.001, 0.01, 0.1, 1, 10, 100, 1000,

10000ppm, mol/L, mg/L

Conductivity

   Range

0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

   Accuracy

±0.5% F.S

   Calibration Points

1 to 5 points

   Calibration Solutions

10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm

   Temperature Compensation

0~100°C, 32~212°F, Manual or Automatic

   Temperature Coefficient

0.0~10.0%/°C

   Compensation Modes

Linear or Pure Water

   Cell Constant

K=0.1, 1, 10

   Normalization Temperature

20 or 25°C

TDS

   Range

0~10ppt

(Max. 20ppt, depending on factor setting)

   Accuracy

±1% F.S

   TDS Factor

0.1~1.0 (Default 0.5)

Salinity

   Range

0~10ppt (Max. 80ppt)

   Accuracy

±1% F.S

   Measurement Modes

Seawater or Practical Salinity

Resistivity

   Range

0~100MΩ

   Accuracy

±1% F.S

   Resolution

0.01, 0.1, 1

Dissolved Oxygen

   Range

0.00~20.00mg/L (or ppm)

   Accuracy

±0.2mg/L

   Resolution

0.01mg/L

   Calibration Points

1 or 2 points

   Temperature Compensation

0~50°C, 32~122°F

   Pressure Correction

60.0~112.5kPa, 450~850mmHg

   Salinity Correction

0~50g/L

% Saturation of Oxygen

   Range

0.0~200.0%

   Accuracy

±2.0%

   Resolution

0.1%

Temperature

   Range

0~105°C, 32~221°F

   Accuracy

±0.5°C, ±0.9°F

   Resolution

0.1°C

   Calibration Points

1 point

   Calibration Range

Measured value ±10°C

Others

   Hold Function

Manual or Automatic

   Stability Conditions

Low or High

   Calibration Due

0 to 31 days

   Power Off

Manual or Automatic (10, 20, 30 minutes)

   Reset Function

Yes

   Memory

Stores up to 500 data sets

   Output

USB Communication Interface

   Connector

BNC, 6-pin Mini Plug

   Display

LCD

   Power Requirements

DC5V, using AC adapters, 220VAC/50Hz

   Dimensions

210(L)×188(W)×60(H)mm

   Weight

1.5kg