<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>NanoDrop &#8211; ACCULAB USA</title>
	<atom:link href="https://acculab-usa.com/product-category/general-lab/nanodrop/feed/" rel="self" type="application/rss+xml" />
	<link>https://acculab-usa.com</link>
	<description>Medical Instruments</description>
	<lastBuildDate>Tue, 08 Oct 2024 18:22:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://acculab-usa.com?v=8</generator>

<image>
	<url>https://acculab-usa.com/wp-content/uploads/2024/06/cropped-faviconV2-32x32.png</url>
	<title>NanoDrop &#8211; ACCULAB USA</title>
	<link>https://acculab-usa.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>NDP-3200 Micro-Spectrophotometer</title>
		<link>https://acculab-usa.com/product/ndp-3200-micro-spectrophotometer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 08 Oct 2024 18:22:27 +0000</pubDate>
				<guid isPermaLink="false">https://acculab-usa.com/acculabusa/?post_type=product&#038;p=50066</guid>

					<description><![CDATA[<strong>Product Code:0203</strong>

<strong>Brand:</strong>NanoDrop

<strong><u>NDP-3200</u></strong>]]></description>
										<content:encoded><![CDATA[<p>NPD2300 ultra-micro nucleic acid analyzer is an instrument used to detect the concentration and purity of DNA and RNA.</p>
<p>The sample size required for each measurement is only 1 to 2 μ l. User can directly add the sample point to the template without colorizing cup or capillary accessories. After the measurement, you can choose to wipe the sample directly or use a pipettor to recover the sample. All steps are simple and fast.</p>
<ul>
<li>NDP3200 is a micro-volume UV spectrophotometer designed (only 3 types of wavelength: 260 nm, 280 nm</li>
</ul>
<p>and 365 nm) for the measurement of nucleic acids and proteins</p>
<ul>
<li>Android system operation, 7 inch touch screen no computer, APP software, simple interface, easy to use</li>
<li>LED light source long-life components</li>
<li>To detect the concentration of bacteria and microorganism are more convenient with the OD600 function</li>
<li>Measures nucleic acid concentration at 260 nm and purity using the ratio 260/280</li>
<li>Measure purified protein concentration at 280 nm</li>
<li>The data can be printed with built-in printer, the data can output via SD-RAM card and USB memory</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NDP-6000F</title>
		<link>https://acculab-usa.com/product/ndp-6000f/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 08 Oct 2024 18:20:44 +0000</pubDate>
				<guid isPermaLink="false">https://acculab-usa.com/acculabusa/?post_type=product&#038;p=49864</guid>

					<description><![CDATA[<div class="product-attr-text"><strong>Product Code:112303</strong></div>
<div class="product-attr-text"><strong>Brand:</strong>NanoDrop</div>
<b>NDP-6000F</b>]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;">NanoDrop Micro-Spectrophotometer</p>
<p>&nbsp;</p>
<ol>
<li>To added the 0.05mm optical path length, and the highest detection concentration up to 15000ng/ulTo added the Fluorescence detection function, which can be used for accurate quantification of extremely low concentration nucleic acid with a lower limit of 0.5pg/µl</li>
</ol>
<ul>
<li>Automatic detect after put down the arm</li>
</ul>
<p>.2. Easy Handling</p>
<ul>
<li>adding sample</li>
<li>measuring sample</li>
<li>quick and easy cleaning</li>
</ul>
<ol start="3">
<li>The patented lifting motor structure makes the liquid column stretch more gentle, preventing the liquid column from breaking due to structural problems. In addition, the structure can effectively solve the instability of reading caused by high concentration sample, especially suitable for precise quantification of protein samples</li>
<li>Android system, 7-inch capacitive touch screen, intuitive APP software, simple and easy to use</li>
<li>To detect the concentration of bacteria and microorganism are more convenient with the OD600 function</li>
<li>New fluorescence detection function for NDP-6000F</li>
</ol>
<p>Fluorescence detection combined with fluorescence quantitative analysis kit, able to accurately quantify DNA, RNA and protein concentration through the specific binding of fluorochrome with target material, and the minimum limit is 0.5pg/u(dsDNA). ​Nano-500 can be compatible with common fluorescence quantitative reagent to provide users with maximum convenience and minimum detection cost.</p>
<ol start="7">
<li>With a 2048-Element linear CCD array detector, the detection and display can be completed in 6s</li>
<li>Equipped with HD touch screen, no need to connect computer.</li>
<li>Longer service life of optical component, intelligent identification of user usage. The light source will auto off after 5 minutes without any operation to extend service life</li>
<li>The result can be printed by a built-in printer or exported via USB for data analysis and storage</li>
</ol>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NDP-3000  NanoDrop/ Ultra Micro-spectrophotometer</title>
		<link>https://acculab-usa.com/product/ndp-3000-nanodrop-ultra-micro-spectrophotometer/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 08 Oct 2024 18:17:48 +0000</pubDate>
				<guid isPermaLink="false">https://acculab-usa.com/acculabusa/?post_type=product&#038;p=49458</guid>

					<description><![CDATA[<h1 class="product_title"></h1>
<div class="product-description">
<div class="product-attr-text"><strong>Product Code:5203</strong></div>
<div class="product-attr-text"><strong><strong>Brand:</strong></strong>NanoDrop</div>
<b>NDP-3000</b>

</div>]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p>1.Light path: 1mm, 0.05mm<br />
2. sample volume requirements: 1~2μ L<br />
3. Light source: Xenon lamp<br />
4. Detector : 2048-element linear silicide CCD array<br />
5. Detection range: 200~850nm<br />
6. Wavelength accuracy: ± 1nm<br />
7. Wavelength resolution: 2 nm (FWHM at Hg 546 nm)<br />
8. Accuracy of absorbance: 0.002 Abs<br />
9. Absorbance accuracy: 1% (0.76 absorbance at 350nm)<br />
10. Absorbance range: 0.02~30Abs, equivalent to 10mm<br />
11. Nucleic acid measurement range: 2~600 ng/μ l, dsDNA<br />
12. Protein measurement range: 0.1~40 mg/ml, BSA<br />
13. Sample measurement time: less than 5 seconds<br />
14. Built-in fiber, to avoid external force caused by fiber collisions caused by the measurement results confusing<br />
15. The measurement results are automatically saved in spreadsheet mode<br />
16. The world&#8217;s unique permanent hard drive to save historical data</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NDP-4000</title>
		<link>https://acculab-usa.com/product/ndp-4000/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 08 Oct 2024 18:17:48 +0000</pubDate>
				<guid isPermaLink="false">https://acculab-usa.com/acculabusa/?post_type=product&#038;p=49462</guid>

					<description><![CDATA[<div class="product-attr-text"><strong>Product Code:52100</strong></div>
<div class="product-attr-text"><strong><strong>Brand:</strong></strong>NanoDrop</div>
<b>NDP-4000</b>]]></description>
										<content:encoded><![CDATA[<p>NDP-4000 Nanodrop (just pedestal mode)<br />
NDP-4000C Nanodrop (add Cuvette mode)</p>
<p>Instrument characteristics Platform material: stainless steel and quartz fiber Data can be transferred via USB port or network No need to warm up, boot at any time Save data permanently, you can export or delete it at any time Built-in WIFI for remote assistance Unlimited print test results Built-in detection system, high-definition touch screenBuilt-in fiber to avoid fiber breakage caused by external force collision, resulting in chaotic measurement results Measurement results are automatically saved to spreadsheet mode Globally unique permanent hard drive save history data function Detection time: less than 5s NDP-4000C    cuvette parameters Trial cuvette specifications (light path): 1/2/5/10mm</p>
<p>Cuvette minimum volume: 50μl</p>
<p>Sample level height: 5mm</p>
<p>Type: Recyclable micro cuvette</p>
<p>Cuvette darkroom: standard cuvette darkroom, suitable for multi-size cuvettes</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>NDP-1000 Nano Drop</title>
		<link>https://acculab-usa.com/product/ndp-1000-nano-drop/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 08 Oct 2024 18:03:17 +0000</pubDate>
				<guid isPermaLink="false">https://acculab-usa.com/acculabusa/?post_type=product&#038;p=49130</guid>

					<description><![CDATA[<div class="product-attr-text"><strong>Product Code:1120</strong></div>
<div class="product-attr-text"><strong><strong><strong>Brand:Nano Drop</strong></strong></strong></div>
<h3> NDP-1000</h3>
&#160;]]></description>
										<content:encoded><![CDATA[<p>1. Direct, easy measurements in less than 5 seconds</p>
<p>2. Require only 0.5~2ul samples</p>
<p>3. No cells or cuvettes and no warm up</p>
<p>4. Optional data output via built-in printer, SD-RAM Card, USB memory</p>
<p>5. Touch screen and panel operation, without computer</p>
<p>6. No dilutions for samples</p>
<p>•  0.5~2.0ul sample onto the test platform with a pipette</p>
<p>• Close the sampling arm</p>
<p>•  Press the &#8220;Measure&#8221; button, the result of the sample will display on the touch screenClean the test platform</p>
<p>•  Press the &#8220;Print&#8221; button, the built-in printer will print the result of sample</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
