<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Atomic Absorption &#8211; ACCULAB USA</title>
	<atom:link href="https://acculab-usa.com/product-category/analytical-lab/atomic-absorption/feed/" rel="self" type="application/rss+xml" />
	<link>https://acculab-usa.com</link>
	<description>Medical Instruments</description>
	<lastBuildDate>Mon, 09 Dec 2024 22:32:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://acculab-usa.com?v=8</generator>

<image>
	<url>https://acculab-usa.com/wp-content/uploads/2024/06/cropped-faviconV2-32x32.png</url>
	<title>Atomic Absorption &#8211; ACCULAB USA</title>
	<link>https://acculab-usa.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AAS4000</title>
		<link>https://acculab-usa.com/product/aas4000/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 08 Oct 2024 17:59:02 +0000</pubDate>
				<guid isPermaLink="false">https://acculab-usa.com/acculabusa/?post_type=product&#038;p=48802</guid>

					<description><![CDATA[<div class="product-attr-text"><strong>Product Code:</strong> 1112</div>
<div class="product-attr-text"><strong>Brand:</strong> Atomic Absorption</div>
<p class="short-info-p">AAS4000</p>
&#160;]]></description>
										<content:encoded><![CDATA[<p>Build-in computerized data processing and LCD: adopting highly integrated micro digital circuit,</p>
<p>which is stable and reliable with the functions of integral holding, peak height and area, auto zero</p>
<p>adjusting, deuterium lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC Built in computer data processing and LCD: adopting highly integrated micro digital circuit,</p>
<p>which is stable and reliablewith the functions of integral holding, peak height and area, auto zero adjusting,</p>
<p>deuterium lamp and background, multilinear and nonlinear curves fitting, various parameters and working</p>
<p>curves displayed in screen and  report printing, etc.</p>
<p>It is equipped with interface for externally linking PC</p>
<p>Good basic line stability: Double-beam system of optimized design can automatically compensate the light  source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift</p>
<p>on the base line stability) and electronic circuit drift so as to reach a good basic line stability.</p>
<p>The cathode lamp needs not be preheated for long time and sample can be analyzed immediately.</p>
<p>It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and</p>
<p>fast analysis of samples.</p>
<p><b>Standard Accessory:</b></p>
<ul>
<li>Oil – free air compressor .</li>
<li>Glass Atomizer  .</li>
<li>One piece of  Cu hollow cathode lamp .</li>
<li>Atomizer Unit .</li>
<li>Burner Unit .</li>
<li>Dust Cover .</li>
<li>Water Separating glass filter .</li>
<li>Titanium Burner … 10 cm</li>
</ul>
<p><b>Optional Accessories:</b></p>
<ul>
<li>Graphite furnace system .</li>
<li>Hydride generator .</li>
<li>Hollow Cathode lamp .</li>
<li>Graphite tube .</li>
<li>Software .</li>
<li>Recirculating Cooling Water System .</li>
<li>PC Work Station System .</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AAS5000</title>
		<link>https://acculab-usa.com/product/aas5000/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 08 Oct 2024 17:59:02 +0000</pubDate>
				<guid isPermaLink="false">https://acculab-usa.com/acculabusa/?post_type=product&#038;p=48803</guid>

					<description><![CDATA[<div class="product-attr-text"><strong>Product Code:</strong> 1113</div>
<div class="product-attr-text"><strong>Brand:</strong> Atomic Absorption</div>
<p class="short-info-p"><b>AAS5000</b></p>

<div style="display: inline-block; float: left; padding: 20px;"><a class="button-link" href="https://acculab-usa.com/acculabusa/wp-content/uploads/2016/12/Acculabusa__AAS-5000A-Series.pdf" target="-blank" rel="noopener">PRINT CATALOGUE</a></div>]]></description>
										<content:encoded><![CDATA[<p>Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)<br />
◆ Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.<br />
◆ Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)</p>
<p>Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.</p>
<p>Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp</p>
<p><b>Position adjusting:</b> the best height of the flame burner and can automatically set the front and rear positions</p>
<p>◆ Fully automated wavelength scanning and peak searching</p>
<p><b>Complete safety protection equipment:</b> the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage</p>
<p>of air and the abnormal flameout</p>
<p>◆ Deuterium lamp and self-absorption background regulation</p>
<p><b>Data processing:</b> super strong database, possesses more than 500 data self-storage and cutoff storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called</p>
<p>◆ <b>Measuring method:</b> flame absorption method and emission method</p>
<p>◆ <b>Result printing:</b> parameter printing, data result printing and diagram printing</p>
<p><b>Complete automatic controlling system </b></p>
<p>With the help of the software, the following can be easily achieved</p>
<p>Selection of the element lamp</p>
<p>Up-down-front-rear adjustment of the lifter</p>
<p>Adjustment of the optical energy</p>
<p>Selection of the slit</p>
<p>Determination of wavelength scanning and peak searching</p>
<p>Selection of the atomizer</p>
<p>Setting of the background deduction method</p>
<p>Controlling of the gas flow</p>
<p>Automatic flaming and flaming out</p>
<p>Setting of the graphite furnace testing method</p>
<p><b>Advanced graphite furnace temperature controlling technology</b></p>
<p>The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process.</p>
<p>The combination of the 3/time fast sampling technique can make more accurate and reliable testing data</p>
<p>The fast heating capacity can improve the flexibility of the elements further</p>
<p>Use the ordinary power source of 220V without need of dynamic power of 380V</p>
<p>The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples</p>
<p>Three grades adjustable gas flow can accustom to more application needs</p>
<p>Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error Safe, reliable and convenient flame system</p>
<p>Epc can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily</p>
<p>Efficient Atomization system enables a higher sensitivity</p>
<p>The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, Abnormal flame occurs,</p>
<p>a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit tempering. Thus it keeps the operation people and equipment from harm and damage.</p>
<p><b>Multi-functional software workstation</b></p>
<p>A workstation that is supported WINDOWS 10</p>
<p>The rich menu brings great convenience to the use of customer</p>
<p>Convenient conversion between different menus makes the operation more easily</p>
<p>Various analytical correction methods provide the users more choices</p>
<p>Basic default parameter settings enable even the beginners can do the normal operation</p>
<p>Flexible storage, editing and printing methods give the user largest support</p>
<p><b>Instrument configuration:</b></p>
<p>Atomic Absorption Spectrophotometer 1pc</p>
<p>Air compressor without noise 1pc</p>
<p>PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)</p>
<p>A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)</p>
<p><b>Standard Accessories:</b></p>
<ul>
<li>PC Work Station .</li>
<li>HP Inkjet Printer .</li>
<li>Oil – free air compressor .</li>
<li>Acetylene Reducing Valve .</li>
<li>One piece of  Cu hollow cathode lamp .</li>
<li>One piece of  Cu hollow cathode lamp .</li>
<li>Air Filter</li>
</ul>
<p><b>Optional Accessories:</b></p>
<ul>
<li>Graphite furnace system .</li>
<li>Hydride generator .</li>
<li>Hollow Cathode lamp .</li>
<li>Graphite tube .</li>
<li>Recirculating Cooling Water System .</li>
<li>Auto Sampler</li>
</ul>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
