DOS-P Series

QUICK OVERVIEW

Product Code: 1193
Brand: Oscilloscope

DOS-P Series


Share this product on social networks

 

  • Six in one: Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbitrary Waveform generator.
  • IP-51 rated for dust, drip and shake proof to withstand harsh environments.
  • Large fuse confirms to European Safety Standard.
  • Battery indicator with easy-changed connect points. Selectable 18650 battery box for matching 18650 battery by yourself.
  • Anti-theft lock hole, tripod fixed hole, hang rope, FLASH light that can be used in darkness.
  • Replaceable BNC safety joints, and additional one set of joints.
  • High bandwidth 70MHz-200MHz Oscilloscope, 1GSa/s sample rate, 2M Memory depth.
  • 25Mz Arb. Waveform Generator, 200 Mesa/s DDS, 12 bit vertical resolution, easy for simulating transducer
  • 6000 Counts DMM, AC/DC voltage, AC/DC current, resistance, break, capacitance, and diode function.
  • FFT spectral analysis; Waveform Math: add, subtract, multiply and divide; X-Y mode; more than 20 automatic measurements; PASS/FAIL Check function, apply to engineering application.
  • Abundant trigger function, double timebase sampling, easy to observe two waveforms in different frequency.
  • Record and replay of more than 1000 waveforms.
  • Large 5.6 inch TFT Color LCD Display; High Resolution(640*480)
  • USB Host/Device 2.0 full-speed interface; support removable disk;  WIFI/LAN Option, easy to control by PC or long-distance.
  • Waveform data can be output in WORD,EXCEL, BMP, JPG as time and voltage.

Technical Specification

Model

DOS-72P

DOS-102P

DOS-152P

DOS-202P

Acquisition
Sample Modes

Real-Time Sample

Acquisition Modes
Normal

Normal data only

Peak Detect

High-frequency and randon glith capture

Average

Wavefom Average, selectable 4,8,16,32,64,128

Inputs
Inputs Coupling

AC, DC, GND

Inputs Impendance

1MΩ±2% ‖20pF±3pF

Probe Attenuation

1X, 10X

Supported Probe Attenuation Factor

1X, 10X, 100X, 1000X

Maximum Input Voltage

CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×)

Horizontal System
Sample Rate Range

1GS/s

Waveform Interpolation

(sin x)/x

Record Length

2M

SEC/DIV Range

4ns/div~2000s/div, in a  2, 4, 8 sequence

2ns/div~2000s/div, in a  2, 4, 8 sequence

Sample Rate and
Delay Time Accuracy

±50ppm over any ≥1ms time interval

Scanning Speed Range

4ns/div to 8ns/div; (-8div x s/div) to 40ms;
20ns/div to 80μs/div;(-8div×s/div) to 40ms;
200μs/div to 40s/div;(-8div×s/div) to 400s;

2ns/div to10ns/div;(-4div×s/div) to 20ms;

Delta Time Measurement Accuracy
(Full Bandwidth)

Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200

Vertical System
Vertical Resolution

8-bit resolution, all channel sampled simultaneously

Volts Range

2mV/div to 100V/div at input BNC

Bandwidth

70MHz

100MHz

150MHz

200MHz

Rise Time at BNC( typical)

5ns

3.5ns

2.3ns

1.8ns

Analog Bandwidth in
Normal and Average
modes at BNC or with probe,
DC Coupled

±400V(100V/div-20V/div);
±50V(10V/div-5V/div);
±40V(2V/div-500mV/div);
±2V(200mV/div-50mV/div);
±400mV(20mV/div-2mV/div);

Math

+, -, *, /, FFT

FFT

Windows:  Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point

Bandwidth Limit

20MHz

Low Frequency Response (-3db)

≤10Hz at BNC

DC Gain Accuracy

±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.

DC Measurement Accuracy,
Average Acquisition Mode

Measurement Type: Average of ≥16 waveforms with vertical position at zero
Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.
Measurement Type: Average of ≥16 waveforms with vertical position not at zero
Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].

Volts Measurement Repeatability,
Average Acquisition Mode

Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

Trigger System
Trigger Types

Edge, Video, Pulse, Slope, Over time, Alternative

Trigger Source

CH1, CH2, AC Line

Trigger Modes

Auto, Normal, Single

Coupling Type

DC, AC, HF Reject, LF Reject, Noise Reject

Trigger Sensitivity
(Edge Trigger Type)

DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
AC: Attenuates signals below 10Hz ;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.

Trigger Level Range

CH1/CH2: ±8 divisions from center of screen;

Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns

CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;

Set Level to 50%(typical)

Operates with input signals ≥50Hz

Video Trigger
Video Trigger Type

CH1, CH2: Peak-to-peak amplitude of 2 divisions;

Signal Formats and Field Rates

Supports NTSC, PAL and SECAM broadcast systems for any field or any line

Holdoff Range

100ns ~ 10s

Pulse Width Trigger
Pulse Width Trigger Mode

Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse

Pulse Width Trigger Point

Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

Pulse Width Range

20ns ~ 10s

Slope Trigger
Slope Trigger Mode

Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope

Slope Trigger Point

Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

Time Range

20ns ~ 10s

Overtime Trigger
Over Time Modee

Rising edge or Falling edge

Time Range

20ns ~ 10s

Alternative Trigger
Trigger on CH1

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger on CH2

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger Frequency Counter
Readout Resolution

6 digits

Accuracy (typical)

±30ppm (including all frequency reference errors and ±1 count errors)

Frequency Range

AC coupled, from 4Hz minimum to rated bandwidth

Signal Source

Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.

Measure
Cursor Measurement

Manual: Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT);
Tracing: The valtage and time at a waveform point;

Auto Measuerment

Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,

Waveform Generator Mode
Frenquency Range

1Hz(DC)~25MHz

DAC Clock

2K~200MHz adjustable

Memory Depth

4KSa

Vertical Resolution

12 Bits

Stability

<30ppm

Amplitude

±3.5V Max.

Output Impedance

50 Ω

Output Current

50mA Ipeak=50mA

System Bandwidth

25M

Harmonic Wave Distortion

-50dBc(1KHz),  -40dBc(10KHz)

General Specifications
Display Resolution

640 horizontal by 480 vertical pixels

Display Contrast

Adjustable (16 gears) with the progress bar

Probe Compensator Output
Output Voltage( typical)

About 2Vpp into ≥1MΩ load

Frequency(typical)

1kHz

Power Supply
Supply Voltage

AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A

Power Consumption

<30W

Environmental
Temperature

Operating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)

Cooling Method

Convection

Humidity

+104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity

Altitude

Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)

Mechanical
Size

260mmmm; 220mm; 75mm

Weight

2.5KG(without Packing)

 

DMM Mode
Max. Resolution

6000 Counts

DMM Testing Modes

Voltage, Current, Resistance, Capacitance, Diode & Continuity

Max. Input Voltage

AC:600V, DC: 800V

Max. Input Current

AC: 10A, DC:10A

Input Impedance

10MΩ

DMM TrendPlot

1.2M  Point

Range

Resolution

Accuracy

Resolution

DC Voltage

60.00mV

±1%±3 digit

10uV

600.0mV

100uV

6.000V

1mV

60.00V

10mV

600.0V

100mV

800V

1V

AC Voltage

60.00mV

±1%±3 digit

10uV

600.0mV

100uV

6.000V

1mV

60.00V

10mV

600.0V

100mV

DC Current

60.00mA

±1%±5 digit

10uA

600.0mA

±1.5%±5 digit

100uA

6.000A

1mA

10.00A

10mA

AC Current

60.00mA

±1%±5 digit

10uA

600.0mA

±1.5%±5 digit

100uA

6.000A

1mA

10.00A

10mA

Resistance

600Ω

±1%±3 digit

0.1Ω

6.000KΩ

60.00KΩ

10Ω

600.0KΩ

1KΩ

6.000MΩ

10KΩ

60.00MΩ

±1%±5 digit

100KΩ

Capacitance

40.00nF

±2%±5 digit

10pF

400.0nF

100pF

4.000uF

1nF

40.00uF

10nF

400.0uF

100nF

Attention: the smallest capacitance value that can be measured in 5nF

Diode

0V~2.0V

ON-OFF test

<10Ω

 

 

 

 

Model

DOS-72E

DOS-102E

DOS-152E

DOS-202E

Acquisition
Sample Modes

Real-Time Sample

Acquisition Modes
Normal

Normal data only

Peak Detect

High-frequency and randon glith capture

Average

Wavefom Average, selectable 4,8,16,32,64,128

Inputs
Inputs Coupling

AC, DC, GND

Inputs Impendance

1MΩ±2% ‖20pF±3pF

Probe Attenuation

1X, 10X

Supported Probe Attenuation Factor

1X, 10X, 100X, 1000X

Maximum Input Voltage

CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×)

Horizontal System
Sample Rate Range

1GS/s

Waveform Interpolation

(sin x)/x

Record Length

2M

SEC/DIV Range

4ns/div~2000s/div, in a  2, 4, 8 sequence

2ns/div~2000s/div, in a  2, 4, 8 sequence

Sample Rate and
Delay Time Accuracy

±50ppm over any ≥1ms time interval

Scanning Speed Range

4ns/div to 8ns/div; (-8div x s/div) to 40ms;
20ns/div to 80μs/div;(-8div×s/div) to 40ms;
200μs/div to 40s/div;(-8div×s/div) to 400s;

2ns/div to10ns/div;(-4div×s/div) to 20ms;

Delta Time Measurement Accuracy
(Full Bandwidth)

Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200

Vertical System
Vertical Resolution

8-bit resolution, all channel sampled simultaneously

Volts Range

2mV/div to 100V/div at input BNC

Bandwidth

70MHz

100MHz

150MHz

200MHz

Rise Time at BNC( typical)

5ns

3.5ns

2.3ns

1.8ns

Analog Bandwidth in
Normal and Average
modes at BNC or with probe,
DC Coupled

±400V(100V/div-20V/div);
±50V(10V/div-5V/div);
±40V(2V/div-500mV/div);
±2V(200mV/div-50mV/div);
±400mV(20mV/div-2mV/div);

Math

+, -, *, /, FFT

FFT

Windows:  Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point

Bandwidth Limit

20MHz

Low Frequency Response (-3db)

≤10Hz at BNC

DC Gain Accuracy

±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.

DC Measurement Accuracy,
Average Acquisition Mode

Measurement Type: Average of ≥16 waveforms with vertical position at zero
Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected.
Measurement Type: Average of ≥16 waveforms with vertical position not at zero
Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div].

Volts Measurement Repeatability,
Average Acquisition Mode

Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions

Trigger System
Trigger Types

Edge, Video, Pulse, Slope, Over time, Alternative

Trigger Source

CH1, CH2, AC Line

Trigger Modes

Auto, Normal, Single

Coupling Type

DC, AC, HF Reject, LF Reject, Noise Reject

Trigger Sensitivity
(Edge Trigger Type)

DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
AC: Attenuates signals below 10Hz ;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.

Trigger Level Range

CH1/CH2: ±8 divisions from center of screen;

Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns

CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;

Set Level to 50%(typical)

Operates with input signals ≥50Hz

Video Trigger
Video Trigger Type

CH1, CH2: Peak-to-peak amplitude of 2 divisions;

Signal Formats and Field Rates

Supports NTSC, PAL and SECAM broadcast systems for any field or any line

Holdoff Range

100ns ~ 10s

Pulse Width Trigger
Pulse Width Trigger Mode

Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse

Pulse Width Trigger Point

Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width

Pulse Width Range

20ns ~ 10s

Slope Trigger
Slope Trigger Mode

Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope

Slope Trigger Point

Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.

Time Range

20ns ~ 10s

Overtime Trigger
Over Time Modee

Rising edge or Falling edge

Time Range

20ns ~ 10s

Alternative Trigger
Trigger on CH1

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger on CH2

Internal Trigger: Edge, Pulse Width, Video, Slope

Trigger Frequency Counter
Readout Resolution

6 digits

Accuracy (typical)

±30ppm (including all frequency reference errors and ±1 count errors)

Frequency Range

AC coupled, from 4Hz minimum to rated bandwidth

Signal Source

Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.

Measure
Cursor Measurement

Manual: Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT);
Tracing: The valtage and time at a waveform point;

Auto Measuerment

Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,

Waveform Generator Mode
Frenquency Range

1Hz(DC)~25MHz

DAC Clock

2K~200MHz adjustable

Memory Depth

4KSa

Vertical Resolution

12 Bits

Stability

<30ppm

Amplitude

±3.5V Max.

Output Impedance

50 Ω

Output Current

50mA Ipeak=50mA

System Bandwidth

25M

Harmonic Wave Distortion

-50dBc(1KHz),  -40dBc(10KHz)

General Specifications
Display Resolution

640 horizontal by 480 vertical pixels

Display Contrast

Adjustable (16 gears) with the progress bar

Probe Compensator Output
Output Voltage( typical)

About 2Vpp into ≥1MΩ load

Frequency(typical)

1kHz

Power Supply
Supply Voltage

AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A

Power Consumption

<30W

Environmental
Temperature

Operating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)

Cooling Method

Convection

Humidity

+104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity

Altitude

Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)

Mechanical
Size

260mmmm; 220mm; 75mm

Weight

2.5KG(without Packing)